Description
„MAGNUM“ opens a new era in roof design as far as cost-effectiveness and design are concerned.This extraordinary large-format tile is manufactured in perfect quality using the latest high-tech procedures. As the innovative and driving force of the entire branch, CREATON uses the most modern European production plant for mega tiles for the manufacturing of „MAGNUM“.
With a tile requirement of 8.4 tiles/m², CREATON offers a tile providing not only exemplary qualities and sensational beauty, but a tile that also sets new standards with regard to cost-effectiveness: „MAGNUM“ redefines the market for large, cost-effective roofs.
Technical data
| Size: | approx. 350 x 485 mm | ||
| min. approx. | on av. approx. | max. approx. | |
| Covering width: | 295 mm | 296 mm | 297 mm |
| Covering length: | 390 mm | 400 mm | 411 mm |
| max. approx. | on av. approx. | min. approx. | |
| Tile requirement: | 8,7 Pcs./m² | 8,5 Pcs./m² | 8,2 Pcs./m² |
| Weight | approx. 4,9 kg/pcs. | approx. 41,6 kg/m² | |
| Small pack: 4 Piece | Pallet: 168 Piece | ||
| LAF-/FLA-values in mm | ||||||||||||
| Ridge tile | DN | 10° | 15° | 20° | 25° | 30° | 35° | 40° | 45° | 50° | 55° | |
| PF | LAF | 110 | 110 | 110 | 100 | 100 | 100 | 90 | 90 | 90 | 90 | |
| 2.5 pcs./m | FLA | 100 | 95 | 90 | 80 | 70 | 60 | 50 | 40 | 30 | 20 | |
| LAF = distance between laths and ridge intersection, FLA = distance between ridge laths Measurements apply to 30/50-laths. Inc ase of 40/60-laths, CREATON will supply the LAF-measurements on demand. | ||||||||||||
| Requirement coverage length | Requirement coverage width |
| Verge tiles, double bead, half-length | Ridge connection ventilation tile, shed tile |
| approx. 2.5 pcs./m | approx. 3.4 pcs./m |
Extensive fluidic tests have confirmed the superior protection against the intrusion of rain of our model „MAGNUM“. The sophisticated interlockings allow for the protection against the intrusion of rain in case of roof pitches of
16° by means of a trussing sheet,
of 14° using a heat-sealed or bonded sub-coverage sheet,
of 12° with a rainproof sub-roof necessary according to our conditions of warranty.
We would be pleased to advise you with regard to the execution of the sub-roof area. In case of lath distances in the
minimum/maximum limit range, it is absolutely necessary to indicate the lath distances in your order!
Minor colour and size deviations are possible due to the natural variations of the raw clay.